cognOlect Dashboard
Manage research projects, experiments, participants, laboratory recordings and research data from one workspace.
Research Overview
Current project and experiment metrics
Active Research Studies
Projects and associated experimental paradigms
Recent Activity
Research provenance and audit records
Researcher Workspace
Manage experimental pipelines, collaborator permissions, ethics versions and analytical workflows.
Projects, Consent & Forms
Define research questions, eligibility rules, study-specific demographic questionnaires and versioned consent forms.
Stimulus Bank & Batteries
Curate multilingual Unicode/IPA items, configure practice and main blocks, and run Categories A–J paradigms.
Audio Lab & Sessions
Inspect waveforms, slice phonetic segments, issue pseudonymous invitation codes and monitor trial capture.
Statistics, Graphs & Reports
Execute parametric and non-parametric tests, plot distributions, and export formula-safe multi-sheet workbooks.
Current Project Specification
Team Collaborators & Role Permissions
Respondent Workspace
View studies to which you have legitimate access, review informed-consent documentation, complete demographic questionnaires and participate in behavioural tasks.
Projects & Studies
Create, edit, archive and manage research projects with full version provenance and access control.
Create Research Project
EEG / EMG Stimulus Trigger & Biosignal Acquisition Policy
Decide which linguistic units emit synchronised EEG / EMG event triggers (One Word, One Letter, or One Numeral) across all test batteries.
Experimental Test Batteries
Select a category to inspect paradigm specifications or launch an end-to-end interactive behavioural session with monotonic performance.now() response-time capture.
Interactive RAN Studio — Numbers & Letters
Measures serial naming speed, visual-verbal retrieval automaticity and inter-item articulation latency across Numbers (Digits), Letters (Alphabetic & Multi-Script) and Alternating Numbers & Letters.
Experiment Runner
Task Instructions
Experimental Block Completed
All trial-level timestamps, raw response times, condition labels and stimulus identifiers have been committed to the project dataset.
Experiment Builder
Configure metadata, trial blocks, randomisation, timing parameters, stimulus mappings and publication readiness checks.
A. Experiment Metadata & Versioning
B. Trial Configuration, Timing & Exclusion Rules
D. Experimental Conditions
C. Stimulus CSV / TSV / TXT / JSON Import
Sample Templates Includedstimulus_id,text,ipa,condition,correct_key,language,frequency_pmw,gloss
F. Preview & Launch
Test the exact trial sequence, fixation timing and response keys in the interactive runner.
Stimulus &Corpus Library
Unicode-safe repository preserving Latin, Devanagari, Perso-Arabic, Multilingual Unicode scripts and IPA transcriptions without destructive normalisation.
Image Asset Library
Store and retrieve research images locally, associated with the active project.
Add Stimulus Item (Preserves Original Codepoints)
Multilingual Stimulus Bank
Corpus Upload & Lexical Concordance
UTF-8 Multi-Script
Upload an authorised UTF-8 corpus (.txt, .csv, .tsv, .json) or download a sample template to see the proper structure.
.txt) or tabular (token_id,text,language,frequency_pmw):Participant Enrollment Registry
Manage study-specific pseudonymous participant identifiers, issue invitation codes and apply transparent exclusion rules. Direct personal identifiers (such as email addresses) are never used as experimental IDs.
Demographic & Language Background
Design project-specific questionnaires with ethical justification for each field, validation rules, and version history.
Add Questionnaire Field
Configured Fields in Current Version (v1.1)
Interactive Questionnaire Preview & Capture
Respondent ViewSubmitted Demographic Records (0)
Audio & Media Laboratory
Inspect acoustic waveforms, record microphone speech with explicit consent, perform non-destructive signal processing, and annotate phonetic tiers.
No Audio Loaded (Upload WAV/MP3, Record Mic, or Load Reference)
Sample Rate: — Hz • Channels: — • Duration: 0.00 s
Signal Purification & Processing
All operations execute on the Web Audio API sample array of the derivative buffer, preserving the original recording untouched.
Processing Provenance History
Acoustic Segmentation & Phonetic Annotation Tiers
seg-ipa-input (Phonetic Tier)
EEG / EMG Laboratory
Acquisition, signal monitoring, processing and export.
Universal EEG / EMG Trigger & Multi-Channel Biosignal Synchronisation
Records stimulus events locally and publishes a shared Lab Streaming Layer (LSL) marker stream; compatible amplifiers can additionally receive native USB-TTL triggers. Actual channel names and sampling rates are taken from the connected device.
EEG / EMG Data Source, Filtering & Epoch Extraction
Connect an LSL stream from compatible vendor software, import a supported recording, or create clearly labelled demonstration data.
Eye-Tracking Laboratory
Tracker connection, gaze acquisition, quality monitoring and analysis.
Integrated Eye-Tracking Laboratory
Connect any eye tracker whose companion application publishes gaze data through LSL, or import a tabular gaze export (CSV/TSV).
Live Eye-Tracker Diagnostics
Stream metadata, channel recognition and incoming measurement checks.
| Measurement | Declared | Received | Valid values |
|---|---|---|---|
| Gaze X | — | — | — |
| Gaze Y | — | — | — |
| Generic pupil | — | — | — |
| Left pupil | — | — | — |
| Right pupil | — | — | — |
Scene Camera
Acquire and record the participant-facing camera independently of the gaze LSL stream.
Recording is saved as an H.264 MP4 video. For verified 30 FPS capture, use 640 × 480 or 640 × 360. Frame timestamps represent acquisition receipt time, not hardware exposure time.
Recording Quality Report
Recording integrity and data completeness assessment
Timestamp Integrity
Sampling Interval Anomalies
Estimated missing samples are heuristic estimates based on timestamp intervals, not verified counts of samples lost by the acquisition device.
Areas of Interest (AOI)
Enter AOI boundaries in the same coordinate units as the selected eye tracker. Dwell is estimated from the timestamps of samples inside each region.
Data Collection & Monitoring
Inspect raw behavioural trial responses, verify idempotent session logs, and apply transparent, reversible outlier exclusions without overwriting raw RT values.
Statistical Analysis Workspace
Genuine mathematical implementations of descriptive, correlational, parametric, ANOVA, categorical, non-parametric and response-time analyses.
.csv, .txt, .tsv, .json) to see the exact column layout, populate your data, and click Browse & Upload Dataset.
trial_id,participant_id,experiment_id,exp_version,session_id,block,stimulus_id,stimulus_text,language,condition,trigger_unit_type,eeg_trigger_code,eeg_trigger_hex,erp_n170_uv,erp_n400_uv,erp_p600_uv,emg_onset_ms,emg_peak_rms_uv,response,correct,raw_rt_ms,word_freq_pmw,stim_len,excluded,exclusion_reason
1. Variable & Cleaning Configuration
2. Dataset Preview & Missing/Excluded Data Accounting
Active Project DatasetA. Descriptive Statistics by Condition
H & I. Raw vs Cleaned RT & Accuracy Analysis
C, D & G. Two-Group Parametric (t, Welch, Paired, z) & Non-Parametric (Mann–Whitney, Wilcoxon)
E & G. One-Way ANOVA, Repeated-Measures ANOVA & Kruskal–Wallis
B. Correlation (Pearson r, Spearman ρ & Matrix)
F. Categorical Data (Chi-Square, Contingency Table & Fisher's Exact)
K. Researcher Interpretation Notes & Methodological Caveats
Note: Statistically significant associations do not establish causation. Enter researcher interpretation notes below to include them in exported reports and reproducibility logs.
Data Visualisation
Generate publication-styled visualisations from live experimental data with sample sizes, 95% confidence intervals, individual observations and PNG/SVG export.
Graph Configuration
Data Export & Report Generator
Export research-ready datasets with full Unicode preservation, comprehensive data dictionaries and spreadsheet formula-injection protection.
1. Configure Export Scope & Security
2. Research Data Dictionary Specification
Automated Research Report Preview
Documentation
Comprehensive operational guide written in British English reflecting the exact implemented workbench architecture.
Settings
Manage your researcher or respondent profile, institutional affiliation, password recovery and backend connection settings.
Profile & Institutional Details
Configuration & Persistence
This desktop edition stores researcher accounts and workspace data locally. No cloud configuration is required.
Privacy & Security
Configure study-specific informed-consent versions, audit participant consent and withdrawal records, and review local data-storage safeguards.
Study-Specific Consent Version Editor
Version: v2.0-2026Recorded Consent & Withdrawal Registry
Local Data Storage & Protection
Database: SQLite
Storage location: Local application data directory
Researcher access: Authenticated local researcher session
Passwords: Hashed using Argon2
Workspace persistence: Automatic local saving and recovery
Network requirement: Not required for local data storage
About cognOlect
cognOlect is an integrated Psycholinguistics and Cognitive Linguistics Research Workbench designed for experimental linguists, cognitive scientists, postgraduate researchers, university teachers and language-documentation specialists worldwide, with dedicated support for under-resourced languages and multi-script communities.
Developer’s Note:
“I intend to make language research tools available to researchers across the globe. cognOlect is being developed to support experimental research, linguistic investigation and reproducible data analysis through an accessible and researcher-centred platform.”
Developer: Farooq Ahmad Mir ( M.Phil., Ph.D - Linguistics)
Core Scientific & Ethical Principles
- Scientific Transparency: Every statistical output reports exact degrees of freedom, test statistics, effect sizes and underlying assumptions without fabricating p-values or claiming causation from correlation.
- Chronometric Honesty: Response times are captured using the browser’s monotonic
performance.now()clock synchronised torequestAnimationFrame. We explicitly document operating-system scheduling, 60Hz/120Hz display refresh quantisation, USB/Bluetooth keyboard polling latency and background-tab throttling. - Multilingual & Script Fidelity: Full Unicode preservation for Latin, Devanagari, Perso-Arabic, and IPA phonetic notation without silent normalisation or truncation.
- Participant Privacy & Pseudonymisation: Participant identity records are separated from experimental trial responses, and study-specific informed consent is version-locked.
Documented Technical & Environment Limitations
- Browser Display Timing vs Laboratory Hardware: Ultra-brief masked priming (<33 ms) is constrained by physical monitor refresh intervals (16.67 ms at 60 Hz). Sub-millisecond hardware trigger studies (EEG/MEG/eyetracking) require dedicated laboratory hardware such as PsychoPy/E-Prime with photodiode verification.
- Acoustic Signal Processing Scope: The Audio Laboratory implements deterministic Web Audio API signal processing (peak normalisation, dB gain, silence trimming/insertion, and high-pass + RMS noise gating). It does not perform neural speech enhancement or forced phonetic alignment (e.g. Montreal Forced Aligner).
- Institutional Ethics & Legal Compliance: Electronic consent tracking supports research governance but does not substitute for formal Institutional Review Board (IRB) or Research Ethics Committee (REC) approval.